High temperature and high efficiency filter before use precautions

Due to high temperature and high efficiency filter used in the organic silica gel and inorganic glue curing process is from the surface inward curing, injection glue height thicker, more difficult to cure, under normal circumstances glue curing time for 3-7 days, if not completely Curing high temperature and high efficiency filter directly into the normal use of high-temperature equipment, will inevitably lead to high temperature plastic cracking, swelling and glue from the frame and so on; for the above problems, the following special programs to deal with the following two:
1, high temperature and high efficiency filter to be normal use after 7 days (more practical high-temperature glue bonding situation);
2, if customers need to immediately install, we recommend customers in the use of high temperature and high efficiency of our filter before the operation must be the following methods:
250 ℃ high temperature resistant filter in the high temperature equipment slowly heated to 100 ℃, and then 2 hours after the shutdown cooling;
Adjust the temperature to 150 ° C for 1 hour and then cool down
Temperature regulation to 200 ℃ 1 hour after the shutdown cooling
Temperature regulation to 250 ° C 1 hour after the shutdown cooling
Finally, slow cooling, you can normally use.
Resistant to 350-400 ℃ high temperature and high efficiency filter in the high temperature equipment, slowly heated to 100 ℃, and then 2 hours after the shutdown cooling;
Adjust the temperature to 150 ° C for 1 hour and then cool down
Temperature regulation to 200 ℃ 1 hour after the shutdown cooling
Temperature regulation to 250 ° C 1 hour after the shutdown cooling
Temperature regulation to 300 ℃ 1 hour after the shutdown cooling
Adjust the temperature to 350 ℃ 1 hour after the shutdown cooling
Adjust the temperature to 400 ℃ 1 hour after the shutdown cooling
Finally, slow cooling, you can normally use